    Four elements of inverter operation

    2023-05-20 11:31:19

    As a precision electronic industrial control device, in order to make the inverter run smoothly and smoothly for a long time, as a professional technician, we also need to have four environmental factors directly affecting the operation of the inverter before the inverter is installed or running. Get started and do a good job of preparation.


    First, the physical environment


    ① Temperature factor


    Temperature has a huge impact on the life and reliability of the electronic components inside the inverter. When using the inverter in a high operating temperature environment, additional cooling and cooling measures must be taken to ensure that the ambient temperature is stable within the range required by the inverter manual (-10 to + 40/45 ° C). In the electric control box, the inverter should generally be installed on the upper part of the box, and it is strictly forbidden to install the heating element close to the bottom of the inverter! In addition, the inverter's own cooling fan should be inspected and cleaned regularly during use.


    ②Humidity factor


    For the harm of such factors, I believe that the majority of colleagues can understand that-when the ambient humidity is greater than 90%, the insulation of the components inside the inverter will deteriorate, which will cause the inverter to malfunction. Therefore, it is necessary to put desiccant in the inverter when necessary.


    ③ Corrosive gas


    Because corrosive gas has a great destructive effect on the electrical insulation performance of the PCB board inside the inverter, plastic product casing, etc., when using the inverter in such an environment, a sealed enclosure that meets the requirements of safety regulations should be used.


    ④ Vibration and shock


    These two kinds of physical phenomena that can cause poor electrical contact of the inverter and the welding of the components also have a greater impact on the normal use of the inverter. Therefore, it is not important to strengthen the daily maintenance and repair work.


    Electrical environment


    ①Prevent electromagnetic interference


    Because the inverter has rectification and inverter links in the work, this work process will inevitably generate a lot of electromagnetic wave interference. These high-frequency electromagnetic waves will have some interference with nearby instruments. For this reason, the instrumentation of the inverter and the same network should be grounded first, and the cables between various electrical components and instruments should be shielded cable, and the shielded layer must be grounded.


    ② Prevent overvoltage at the input


    Although most inverter power supply input terminals have over-voltage protection function, if the high-voltage input terminal of the inverter is applied for a long time, it will often cause damage to related components (such as varistor and rectifier) inside the inverter. For power sources with frequent and large fluctuations in power supply voltage, voltage regulators should be considered.


    Third, grounding


    Proper grounding of the inverter is an important means to improve system sensitivity and suppress noise interference. The grounding terminal G (also marked with E) of the inverter should be as small as possible. The cross-sectional area of the grounding wire should not be less than 2mm2, and the length should be controlled within 20m. In addition, it should be pointed out that the shield of the signal input line of the inverter should be connected to the G (or E) terminal, and the other end must not be connected to the ground, otherwise it will cause fluctuations in signal changes and system oscillation.


    Fourth, lightning protection


    Lightning absorption and discharge circuits are generally provided in the inverter to prevent damage to the inverter caused by instant lightning intrusion. However, in the actual operation process, especially when the power line of the inverter is introduced overhead, it is not enough to rely solely on the lightning protection circuit inside the inverter. For this reason, in the lightning active area, and the power supply of the inverter is an overhead line, you should install a lightning arrester (manufacturer's option) for the inverter at the incoming line, or embed zinc plating at a distance of 20m from the inverter according to the requirements Lightning protection for grounded steel pipes.


    通用變頻器


    label

    QR code

    The public,

    Mobile station
    The public, Mobile station

    Contact

    未標題-8.png 0755-81719517
    未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
    未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

    Navigation

    Home          About

    Product      Case

    Solution      Service

    Job      News

    Contact          

    Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
    主站蜘蛛池模板: 色噜噜人体337p人体| 中文字幕美人妻亅u乚一596| 国产亚洲精品久久久久久久久| 成年美女黄网站色奶头大全| 国语精品自产拍在线观看网站| 成在线人免费无码高潮喷水| av无码免费一区二区三区| 无遮挡aaaaa大片免费看| 香蕉伊蕉伊中文在线视频| 无码国产玉足脚交极品播放| 国产在线欧美日韩精品一区| 日本理伦片午夜理伦片| 午夜成人无码福利免费视频| 好吊视频一区二区三区 | 正在播放国产剧情亂倫| s级爆乳玩具酱国产vip皮裤| 中文字幕 亚洲 无码 在线| 久久久久人妻一区精品| 免费无码a片一区二三区| 天天摸天天做天天爽水多| 久久久欧美精品激情| 欧美成 人版中文字幕| 精彩国产萝视频在线| 久久综合久久美利坚合众国| 亚洲色欲色欱WWW在线| 精品视频不卡免费观看| 牛牛在线视频| 国产成人综合在线观看不卡| 国产明星裸体xxxx视频| 欧美亚洲日本国产综合在线| 国产成人精品免费视频app软件| 日本无码欧美一区精品久久| 成年女人午夜毛片免费视频| 婷婷国产成人精品视频| 日本强伦姧熟睡人妻完整视频| av午夜福利一片免费看久久| av一本久道久久综合久久鬼色| 乱中年女人伦| 粗大的内捧猛烈进出| 国精产品一区一区三区有限公司| 精品国产av一区二区三区|