    How to choose the right inverter (5 tips)

    2023-05-20 12:02:10

    With the rapid development of the process in the field of industrial automation, it has also been widely used as a frequency converter for frequency conversion debugging. As an important role of frequency conversion speed regulation and energy saving, the frequency converter's main role is to control the power control equipment of the AC motor by changing the frequency mode of the working power of the motor. Its advantages not only improve the level of process production for enterprises, but also play an important role in energy conservation for enterprises. So how do you choose the right inverter? Today, the inverter manufacturer will introduce the purchase skills of the inverter.


    How to choose the right inverter (5 tips for choosing an inverter)


    First of all, from what aspects should I choose the inverter?


    Choose the type of inverter. According to the requirements of the type of production machinery, speed range, static speed accuracy, and starting torque, decide which inverter is most suitable for the control method. The so-called appropriate is not only easy to use, but also economical to meet the basic conditions and requirements of the process and production.


    How to judge the choice of inverter?


    1. The motor to be controlled and the inverter itself


    The number of poles of the motor. Generally, the number of motor poles should be no more than 4; otherwise, the capacity of the inverter should be increased appropriately. Torque characteristics, critical torque, acceleration torque. In the case of the same motor power, the inverter specifications can be selected by derating relative to the high overload torque mode. Electromagnetic compatibility. In order to reduce the interference of the main power supply, a reactor can be added to the intermediate circuit or the input circuit of the frequency converter during use, or a pre-isolation transformer can be installed. Generally, when the distance between the motor and the inverter exceeds 50m, reactors, filters or shielded protective cables should be inserted between them.


    2. Selection of inverter power


    The system efficiency is equal to the product of the inverter efficiency and the motor efficiency. Only when both are working at a higher efficiency, the system efficiency is higher. From the perspective of efficiency, when selecting the power of the inverter, pay attention to the following points:


    It is most suitable when the power value of the inverter is equal to the power value of the motor, so that the inverter can operate at a high efficiency value.


    When the power classification of the inverter is different from that of the motor, the power of the inverter should be as close as possible to the power of the motor, but it should be slightly larger than the power of the motor.


    When the motor is frequently started, braked, or under heavy load starting and more frequently, a large-level inverter can be selected to use the inverter for long-term and safe operation.


    After testing, the actual power of the motor does have surplus. Consider using an inverter with a power less than that of the motor, but pay attention to whether the instantaneous peak current will cause overcurrent protection.


    When the power of the inverter and the motor are different, the settings of the energy-saving program must be adjusted accordingly to achieve a higher energy-saving effect.


    3. Selection of inverter box structure


    The box structure of the inverter should be adapted to the environmental conditions, that is, temperature, humidity, dust, acidity, corrosive gas and other factors must be considered. The following types of structures are commonly available for users to choose from:


    The open-type IPOO type itself has no chassis, and is suitable for installation in the electric control box or on the screen, plate, and rack in the electrical room. Especially when multiple inverters are used in a centralized manner, this type is better, but the environmental requirements are higher; The enclosed IP20 type is suitable for general use, and may have a small amount of dust or a little temperature and humidity; the sealed IP45 type is suitable for environments with poor industrial site conditions; the sealed IP65 type is suitable for poor environmental conditions, with water, dust and certain corrosivity Gas occasions.


    4. Determination of inverter capacity


    Reasonable capacity selection is itself a measure of energy saving and consumption reduction. Based on available information and experience, there are three simpler methods:


    The actual power of the motor is determined. First determine the actual power of the motor to select the capacity of the inverter.


    Formula method. When one inverter is used for multiple motors, it should meet: at least the influence of the starting current of one motor must be considered to avoid the inverter overcurrent trip.


    Motor rated current method inverter. The process of inverter capacity selection is actually the best matching process between the inverter and the motor. The most common and safer is to make the capacity of the inverter greater than or equal to the rated power of the motor, but the actual matching should consider the motor's What is the difference between the actual power and the rated power? Usually, the selected capacity of the equipment is too large, but the actual required capacity is small. Therefore, it is reasonable to choose the inverter according to the actual power of the motor. Avoid choosing the inverter too large, which will increase the investment. .


    For light loads, the inverter current should generally be selected according to 1.1N (N is the rated current of the motor), or the maximum motor power matching the output power rating of the inverter marked in the product by the manufacturer.


    5. Main power supply


    Power supply voltage and fluctuation. Special attention should be paid to adapt to the setting value of the inverter's low voltage protection, because in actual use, there is a greater possibility that the grid voltage is lower.


    Main power frequency fluctuation and harmonic interference. Interference in this area will increase the heat loss of the inverter system, resulting in increased noise and reduced output.


    When the inverter and motor are working, their own power consumption. When designing the main power supply of the system, both power consumption factors should be taken into account.


    Frequency converter manufacturer


    label

    QR code

    The public,

    Mobile station
    The public, Mobile station

    Contact

    未標題-8.png 0755-81719517
    未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
    未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

    Navigation

    Home          About

    Product      Case

    Solution      Service

    Job      News

    Contact          

    Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
    主站蜘蛛池模板: 国产欧洲精品自在自线官方| 欧美专区日韩视频人妻| 无码h黄肉3d动漫在线观看| 国产热久久精| 色综合久久蜜芽国产精品| 亚洲欧美日韩综合久久| 久久精品这里热有精品| 日韩中文字幕国产精品| 韩国三级在线 中文字幕 无码| 99国产在线精品视频| 麻豆亚洲精品一区二区| 亚洲色偷精品一区二区三区| 国产精品久久久一区二区| 他用舌头给我高潮喷水在线| 无码少妇a片一区二区三区| 裸身美女无遮挡永久免费视频| 情侣激情18内射骚话国产| 人妻一区二区三区三区| 国产蜜臀av在线一区尤物 | 亚洲精品久久| 最新中文乱码字字幕在线| 男人猛躁进女人免费播放| 老女人老熟女亚洲| 亚洲欧美综合中文| 无码精品一区二区三区在线| 精品含羞草免费视频观看| 动漫av网站免费观看| 国产精品黑色丝袜在线观看| 制服丝袜人妻综合第一页| 亚洲最大成人综合网720p| 国产高清乱理伦片中文小说| 高清中文字幕国产精品| 蜜桃传媒av免费观看麻豆| 又色又爽又黄的视频女女| 午夜天堂一区人妻| 无码任你躁久久久久久老妇| 亚洲 自拍 欧美 日韩 丝袜| 亚洲自偷自偷图片自拍| 最近中文字幕国产精选| 欧美国产激情18| 国产不卡福利片在线观看|