    location : Home > News > Technical information

    You should pay attention to these shortcomings of frequency converter

    2023-05-20 12:59:47

    The wiring distance between the motor and the frequency converter is too long, causing the new motor to burn


    Burning two new motors together! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, and the fluctuation is 20% - 50%. The frequency converter is burnt out in a 35Hz turn to turn short circuit. The grid voltage is very stable, 720V. The distance between the motor and the frequency converter is 120m. The input and output terminals of the frequency converter are all equipped with reactors. The motor current is very small, and the ambient temperature is about - 10 degrees, which can eliminate the cause of motor overheating. What is the cause of this situation that may cause motor failure?


    Analysis reasons: the current of the load motor is not large, which is caused by the frequency converter. The inverter is too far away from the motor. The harmonic of the output current of the inverter breaks through the insulation between the two parts, resulting in a short circuit. The quality of the current and voltage at the motor side can be measured with an oscilloscope.


    The cable is long and there is a certain distributed capacitance between the cable and the earth. This capacitance will affect the transmission of electricity, resulting in a certain phase shift between the current and the voltage, which will make the voltage on the motor (peak can be seen by oscilloscope, but can not be seen by ordinary multimeter), and the high voltage will break down the motor winding.


    Solution: if the withstand voltage is not enough to burn the motor, we can use the frequency converter with international certification (CE, UL) and suitable reactor to avoid this problem.


    Does the frequency converter affect the motor


    Ordinary asynchronous motors are designed according to constant frequency and constant voltage, which can not fully meet the requirements of variable frequency speed regulation. The following is the influence of frequency converter on motor:


    1. Efficiency and temperature rise of motor


    No matter what kind of frequency converter, harmonic voltage and current will be produced in different degrees during operation, which makes the motor run under non sinusoidal voltage and current. According to the information, at present


    For example, the commonly used sine wave PWM frequency converter has zero low order harmonics, and the remaining high-order harmonic components which are about twice the carrier frequency are 2U + 1 (U is the modulation ratio).


    Higher harmonic will cause the increase of stator copper loss, rotor copper (aluminum) loss, iron loss and additional loss, especially rotor copper (aluminum) loss. Because the asynchronous motor is rotating at the synchronous speed corresponding to the fundamental frequency, the rotor loss will be very large after the high harmonic voltage cuts the rotor bar with large slip. In addition, additional copper consumption due to skin effect should be considered. These losses will make the motor generate extra heat, reduce efficiency and reduce output power. If the ordinary three-phase asynchronous motor is operated under the condition of non sinusoidal power supply output by frequency converter, its temperature rise will generally increase by 10% - 20%.


    2. The problem of motor insulation strength


    At present, many small and medium frequency converters adopt PWM control mode. Its carrier frequency is about several thousand to more than ten kilohertz rise rate, which is equivalent to the steep impulse voltage applied to the motor, so that the turn to turn insulation of the motor can withstand 4-6 times of the voltage. Superimposed on the running voltage of the motor, it will pose a threat to the insulation of the motor to the ground. The stator winding of the motor should bear a very high voltage in addition to the repeated impact of high voltage Accelerated aging of rectangular chopper generated by frequency converter


    3. Harmonic electromagnetic noise and vibration


    The vibration and noise caused by electromagnetic, mechanical, ventilation and other factors will become more complex when the ordinary asynchronous motor is powered by frequency converter. The time harmonics contained in the frequency conversion power supply interfere with the inherent space harmonics of the electromagnetic part of the motor, forming various electromagnetic exciting forces. When the frequency of electromagnetic force wave is consistent with or close to the natural vibration frequency of the motor body, resonance will occur, which will increase the noise. Due to the wide range of operating frequency and wide range of rotating speed, the frequency of various electromagnetic force waves is difficult to avoid the natural vibration frequency of each component of the motor.


    4. Adaptability of motor to frequent starting and braking


    Since the motor can be started without impact current at a very low frequency and voltage, and can be quickly braked by various braking methods provided by frequency converter, which creates conditions for frequent starting and braking. Therefore, the mechanical system and electromagnetic system of the motor are under the action of cyclic alternating force, which brings about the mechanical structure and insulation structure Fatigue and accelerated aging problems.


    Frequency converter will produce high odd harmonic


    The 5th and 7th times have great influence on the frequency converter and motor. Usually, in order to reduce the influence of harmonics, reactors and absorption capacitors will be added. Filter can also be added at the output end of frequency converter.


    How to calculate the harmonic power of inverter fed motor?


    Method 1


    The amplitude and phase of each harmonic of voltage and current are obtained by Fourier transform. The active power of each harmonic is calculated according to P = √ 3uicos φ. The harmonic power is obtained by adding the active power of all harmonics.


    Method 2


    The total active power is measured, and the fundamental amplitude and phase of voltage and current are obtained by Fourier transform. The fundamental active power is calculated according to P = √ 3uicos φ. The harmonic power is obtained by subtracting the fundamental active power from the total active power.


    Generally, the higher the harmonic frequency is, the lower the accuracy is. The second method is recommended.


    Influence of inverter harmonics on motor and improvement measures


    1、 The reason of motor damage is that the frequency converter produces a high peak voltage on the stator winding of the motor. The amplitude of the peak voltage exceeds the insulation strength of the winding, resulting in winding damage. The magnitude of the peak voltage will be more than three times the rated operating voltage of the frequency converter, for example, for rated voltage 3


    General purpose frequency converter


    label

    QR code

    The public,

    Mobile station
    The public, Mobile station

    Contact

    未標題-8.png 0755-81719517
    未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
    未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

    Navigation

    Home          About

    Product      Case

    Solution      Service

    Job      News

    Contact          

    Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
    主站蜘蛛池模板: 美女高潮无遮挡免费视频| 少妇高潮惨叫喷水在线观看| 人人曰人人做人人| 亚洲日韩av无码中文字幕美国| 女人裸体性做爰视频| 午夜福利伦伦电影理论片在线观看 | 亚洲精品专区成人网站| 成人做受120秒试看试看视频| 欧美激情猛片xxxⅹ大3| 免费无人区男男码卡二卡| 欧美孕妇乳喷奶水在线观看| 免费无码观看的av在线播放| 在线亚洲专区高清中文字幕| 国产超碰无码最新上传| 精品国产这么小也不放过| 最美女人体内射精一区二区| 青青草国产线观看| 国产在线精品一区二区不卡麻豆 | 在线天堂最新版资源| 久久精品岛国AV一区二区无码 | 无码AV无码免费一区二区| 国产高清自产拍av在线| 一区二区不卡国产精品| 无码精品国产VA在线观看DVD| 亚洲精品无码久久久久牙蜜区| 天码欧美日本一道免费| 看免费真人视频网站| 成人免费无码大片a毛片抽搐| 永久免费的av在线电影网| wwww亚洲熟妇久久久久| 国产午夜精品理论大片| 精品无人乱码一区二区三区的特点| 99在线精品免费视频九九视| 一区三区不卡高清影视| 东京热人妻丝袜无码AV一二三区观| 久久综合88熟人妻| 久久99九九精品久久久久齐齐| 国产AV无码专区亚洲AV潘金链| 国产精品a无线| 久久人人97超碰国产公开| 久久精品国产99久久香蕉|