    Four control methods of frequency converter to motor

    2023-05-20 13:13:50

    U/f constant control U/f control is to change the voltage of the motor power supply while changing the frequency of the motor power supply to keep the motor magnetic flux constant. In a wide range of speed regulation, the efficiency and power factor of the motor do not drop. Because it is the ratio of control voltage (Voltage) to frequency (Frequency), it is called U/f control. The main problem of constant U/f control is poor low-speed performance. When the speed is extremely low, the electromagnetic torque cannot overcome the large static friction force, and cannot properly adjust the torque compensation of the motor and adapt to the change of the load torque; the second is Can not accurately control the actual speed of the motor. Since the constant U/f inverter is speed open loop control, it can be seen from the mechanical characteristic diagram of the asynchronous motor that the set value is the stator frequency, which is the ideal no-load speed, and the actual speed of the motor is determined by the slip rate, so U/ The stability error existing in the constant control mode cannot be controlled, so the actual speed of the motor cannot be accurately controlled.


    Slip frequency control The slip frequency is the difference frequency between the AC power frequency applied to the motor and the motor speed. According to the stable mathematical model of asynchronous motor, when the frequency is constant, the electromagnetic torque of the asynchronous motor is proportional to the slip rate, and the mechanical characteristic is a straight line.


    Slip frequency control is to control torque and current by controlling the slip frequency. Slip frequency control needs to detect the speed of the motor to form a speed closed loop. The output of the speed regulator is the slip frequency, and then the sum of the motor speed and the slip frequency is used as the given frequency of the inverter. Compared with U/f control, its acceleration and deceleration characteristics and the ability to limit overcurrent are improved. In addition, it has a speed regulator, which uses speed feedback to form a closed-loop control, and the static error of the speed is small. However, to achieve steady-state control of the automatic control system, good dynamic performance cannot be achieved.


    Vector control Vector control is also called field-oriented control. It was first proposed by F.Blasschke and others in West Germany in the early 1970s, and explained this principle by comparing DC motors and AC motors. This created a precedent for AC motors and equivalent DC motors. The method of vector control frequency conversion speed regulation is to change the stator AC currents Ia, Ib, Ic of the asynchronous motor in the three-phase coordinate system. Through the three-phase-two-phase transformation, it is equivalent to the alternating current Ia1 and Ib1 in the two-phase stationary coordinate system, and then through the rotation transformation according to the rotor magnetic field orientation, it is equivalent to the direct current Im1, It1 (Im1 is equivalent to the synchronous rotating coordinate system). It is the excitation current of the DC motor; It1 is equivalent to the armature current of the DC motor), and then imitate the control method of the DC motor to obtain the control value of the DC motor, and realize the control of the asynchronous motor through the corresponding coordinate inverse transformation. The emergence of vector control method makes asynchronous motor variable frequency speed regulation in an all-round superior position in the field of motor speed regulation. However, vector control technology requires correct estimation of motor parameters, and how to improve the accuracy of parameters is a topic of constant research.


    Direct Torque Control In 1985, Professor DePenbrock from Ruhr University in Germany first proposed the theory of direct torque control. This technology largely solves the deficiencies of vector control. It does not indirectly control the rotation by controlling the current, flux, etc. But the torque is directly controlled as the controlled quantity. The advantage of torque control lies in the fact that torque control is to control the stator flux, essentially does not need speed information, the control is robust to all motor parameter changes except the stator resistance; the introduced stator flux observation The device can easily estimate the synchronous speed information, so it can easily realize the speed sensorless, this kind of control is called the speed sensorless direct torque control.


    Frequency converter manufacturer


    label

    QR code

    The public,

    Mobile station
    The public, Mobile station

    Contact

    未標題-8.png 0755-81719517
    未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
    未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

    Navigation

    Home          About

    Product      Case

    Solution      Service

    Job      News

    Contact          

    Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
    主站蜘蛛池模板: 欧美精品中文字幕亚洲专区| 中文字幕人妻伦伦精品| 亚洲精品国产suv| 亚洲精品无码av黄瓜影视| 中文字幕人妻精品在线| 99久久亚洲综合精品成人网| 亚洲三级高清免费| 国内九一激情白浆发布| 午夜DY888国产精品影院| 看免费真人视频网站| 四虎永久在线精品8848a| 亚洲乱理伦片在线观看中字| 一本一道久久综合狠狠老| 国产无套一区二区三区浪潮| 久久综合亚洲色一区二区三区| 免费av深夜在线观看| 亚洲色大成网站WWW国产| 国产亚洲成年网址在线观看| 天天躁夜夜躁狠狠久久成人网| 未满十八18禁止免费网站| 精品三级久久久久电影网| 老司机午夜福利视频| 国产女人喷潮视频在线观看| 国产乱人伦偷精品视频下| 亚洲国产成人精品青青草原导航| 国产精品白丝久久av网站| 伊人久久大香线蕉AV网禁呦| 亚洲国产另类久久久精品小说| 免费裸体黄网站18禁免费| 日韩不卡手机视频在线观看| 私人毛片免费高清影视院| 无码人妻少妇久久中文字幕| 狠狠爱无码一区二区三区| 推油少妇久久99久久99久久| 国产一卡2卡3卡四卡精品网站| 国产日产欧美最新| 香蕉久久夜色精品国产尤物| 怡红院一区二区三区在线| 我把护士日出水了视频90分钟| 99在线精品免费视频| 免费现黄频在线观看国产|