    How is the leakage of motor using frequency converter?

    2023-05-20 13:14:30

    1、 The inverter output is controlled by PWM (pulse width modulation, similar to high-speed switch), so leakage current with high frequency will occur.


    The PE points of frequency converter, front power supply transformer and motor must be connected together, and then be grounded.


    The frequency converter is a high frequency square wave voltage output, because there is an equivalent capacitance between the motor inner coil and the motor shell, resulting in leakage current. If not grounded or poorly grounded, there will be leakage.


    The factors affecting the leakage current are as follows:


    (1) Leakage current of cable, leakage current of leakage breaker and filter. The leakage current of the cable length of frequency converter and motor.


    (2) Leakage current of filter (including frequency converter).


    (3) Leakage current of motor.


    Some site use frequency converter control motor, there will be leakage problems, leakage voltage has dozens of volts to 200 volts. In view of this problem, the causes of this phenomenon are analyzed as follows:


    2、 According to the functional block diagram of motor operation controlled by frequency converter, the three-phase power supply is transmitted to the inverter bridge (IGBT) after being rectified by the converter rectifier bridge, and then the motor is controlled by the three-phase AC with adjustable output frequency and voltage of the inverter bridge.


    The alternating current with a difference of 120 degrees between three phases flows through the three-phase stator coil winding of the motor to produce a rotating magnetic field, which makes the rotor of the motor rotate automatically under the action of the rotating magnetic field of the stator winding.


    After the three-phase stator winding of the motor flows through the current, the rotating magnetic field is generated. According to the principle of electromagnetic induction, the shell of the motor will produce the induced electromotive force. The magnitude of the induced electromotive force depends on the switching frequency of IGBT and C × DV / dt (related to the speed of IGBT switch). If the induced electromotive force is large, people will feel shocked when they touch it. Theoretically, the higher the switching frequency of IGBT is, the higher the effective value of induced electromotive force (i.e. induced voltage) of motor shell, and the higher the control accuracy and dynamic response of frequency converter to motor, the greater the feeling of being electrified after human touch; on the contrary, the lower the switching frequency of IGBT, the lower the effective value (induced voltage) of induced electromotive force (induced voltage) of motor shell, and the higher the control precision and dynamic response of inverter to motor And then the less you feel electrified.


    Due to the operation of asynchronous motor, the motor shell will have induced voltage (i.e. the so-called leakage). Therefore, the motor manufacturer will install a grounding terminal in the junction box when the motor leaves the factory, so as to facilitate the user to connect the ground to eliminate its induced electromotive force (i.e. eliminate the induced leakage voltage), so as to solve the feeling of being electrified when the human body contacts the motor.


    When the motor is running at power frequency, the switching frequency of power frequency is about 50 Hz, which is very low, so there is almost no sense of leakage in general (unless the motor insulation is very poor). When the frequency converter is controlled, the switching frequency is much higher than the power frequency, so when the frequency converter controls the motor rotation, the motor shell will have the feeling of leakage.


    General purpose frequency converter


    label

    QR code

    The public,

    Mobile station
    The public, Mobile station

    Contact

    未標題-8.png 0755-81719517
    未標題-10.png0755-81719530 未標題-11.pngamb@ambition.com.cn
    未標題-12.pngFloor 1, 5 and 6, building 7, lijincheng science and technology industrial park, gongye dong road, longhua new district, shenzhen

    Navigation

    Home          About

    Product      Case

    Solution      Service

    Job      News

    Contact          

    Copyright © Shenzhen Ambition Electronic Co., Ltd Record number:備案號:粵ICP備12045920號
    主站蜘蛛池模板: 成人片黄网站a毛片免费观看| 高清国产av一区二区三区| 国产精品一区二区亚瑟不卡| 区产品乱码芒果精品综合| 无遮掩60分钟从头啪到尾 | 99国产欧美另类久久久精品| 97欧美精品系列一区二区| 国产精品无码无片在线观看3d| 亚洲免费观看在线美女视频| 俄罗斯老熟妇性爽xxxx| 欧洲熟妇色xxxx欧美老妇多毛图片| 中国老熟女重囗味hdxx| 亚洲人成伊人成综合网76| 人妻精品久久久久中文字幕69| 内射极品少妇xxxxxhd| 亚洲欧美中文字幕国产| 正在播放酒店约少妇高潮| 亚洲成av人片在www鸭子 | 色噜噜狠狠一区二区三区果冻| 精品视频国产香蕉尹人视频| 亚洲AV永久无码精品秋霞电影影院| 中文字幕亚洲欧美专区| 亚洲444kkkk在线观看| 亚洲va久久久噜噜噜久久4399| 国产亚洲精品成人aa片新蒲金 | 性欧美丰满熟妇xxxx性| 无码激情亚洲一区| 亚洲国产成人精品无码区二本| 国产av一区二区三区| 国产日产欧产精品品不卡| 国产在线精品一区二区夜色| 国产成人免费ā片在线观看| 丁香五月激情综合色婷婷| 免费看成人欧美片爱潮app| 精品国产乱码久久久久久红粉| 久久精品无码专区免费 | 亚洲精品喷潮一区二区三区| 四虎永久在线精品8848a| 日本高清在线观看WWW色| 国产乱国产乱老熟300部视频| 真实国产精品视频400部|